Welcome to ironic-staging-drivers’s documentation!

Contents:

Ironic Staging Drivers

The Ironic Staging Drivers is used to hold out-of-tree Ironic drivers which doesn’t have means to provide a 3rd Party CI at this point in time which is required by Ironic.

The intention of this project is to provide a common place for useful drivers resolving the “hundreds of different download sites” problem.

What the Ironic Staging Drivers is not

  • The Ironic Staging Drivers is not a project under Ironic’s governance, meaning that the Ironic core group is not responsible for the code in this project (even though, some individuals that work in this project also hold core status in the Ironic project).
  • This project is not a place to dump code and run away hoping that someone else will take care of it for you. Drivers included in this project should be maintained and have their bugs fixed quickly. Therefore, driver owners are going to be asked to “babysit” their driver.

How to contribute

We want to make sure that the Ironic Staging Drivers project is a welcoming and friendly place to contribute code. Therefore, we want to avoid bureaucratic processes as much as possible. If you want to propose a driver to be included in the repository: Just submit the code!

How do I submit the code?

  1. Before we can accept your patches, you’ll have to agree to a contributor license agreement.

  2. Learn about how to use our Gerrit review system.

  3. Get the code:

    git clone https://opendev.org/x/ironic-staging-drivers
    
  4. Make your changes and write a nice commit message explaining the change in details.

  5. Submit the code!

Available drivers

Wake-On-Lan driver

Overview

Wake-On-Lan is a standard that allows a computer to be powered on by a network message. This is widely available and doesn’t require any fancy hardware to work with [1].

The Wake-On-Lan driver is a testing driver not meant for production. And useful for users that wants to try Ironic with real bare metal instead of virtual machines.

It’s important to note that Wake-On-Lan is only capable of powering on the machine. When power off is called the driver won’t take any action and will just log a message, the power off require manual intervention to be performed.

Also, since Wake-On-Lan does not offer any means to determine the current power state of the machine, the driver relies on the power state set in the Ironic database. Any calls to the API to get the power state of the node will return the value from the Ironic’s database.

Requirements

  • Wake-On-Lan should be enabled in the BIOS

Configuring and Enabling

  1. Add staging-wol to the list of enabled_hardware_types in /etc/ironic/ironic.conf. Also enable the staging-wol power interface and the fake management interface. For example:

    [DEFAULT]
    enabled_hardware_types = staging-wol,ipmi
    enabled_management_interfaces = fake,ipmitool
    enabled_power_interfaces = staging-wol,ipmitool
    
  2. Restart the Ironic conductor service:

    service ironic-conductor restart
    

Registering a node

Nodes configured for Wake-On-Lan driver should have the driver property set to staging-wol.

The node should have at least one port registered with it because the Wake-On-Lan driver will use the MAC address of the ports to create the magic packet [2].

The following configuration values are optional and can be added to the node’s driver_info as needed to match the network configuration:

  • wol_host: The broadcast IP address; defaults to 255.255.255.255.
  • wol_port: The destination port; defaults to 9.

Note

Say the ironic-conductor is connected to more than one network and the node you are trying to wake up is in the 192.0.2.0/24 range. The wol_host configuration should be set to 192.0.2.255 (the broadcast IP) so the packets will get routed correctly.

The following sequence of commands can be used to enroll a node with the Wake-On-Lan driver.

  1. Create node:

    openstack baremetal node create --driver staging-wol \
        --driver-info wol_host=<broadcast ip> \
        --driver-info wol_port=<destination port>
    

The above command ironic node-create will return UUID of the node, which is the value of $NODE in the following command.

  1. Associate port with the node created:

    openstack baremetal port create --node $NODE <MAC address>
    
Additional requirements
  • Boot device order should be set to “PXE, DISK” in the BIOS setup
  • BIOS must try next boot device if PXE boot failed
  • Cleaning should be disabled, see [3].
  • Node should be powered off before start of deploy

AMT drivers

Overview

AMT (Active Management Technology) drivers extend Ironic’s range to the desktop. AMT/vPro is widely used in desktops to remotely control their power, similar to IPMI in servers.

AMT drivers use WS-MAN protocol to interact with AMT clients. They work on AMT 7.0/8.0/9.0. AMT 7.0 was released in 2010, so AMT drivers should work on most PCs with vPro.

The staging-amt hardware type uses AMT for power and boot device management.

Set up your environment

A detailed reference is available in Intel Active Management Technology.

A short guide follows below:

  • Set up AMT Client

    • Choose a system which supports Intel AMT / vPro. Desktop and laptop systems that support this can often be identified by looking at the “Intel” tag for the word vPro.
    • During boot, press Ctrl+P to enter Intel MEBx management.
    • Reset password – default is admin. The new password must contain at least one upper case letter, one lower case letter, one digit and one special character, and be at least eight characters.
    • Go to Intel AMT Configuration:
      • Enable all features under SOL/IDER/KVM section
      • Select User Consent and choose None (No password is needed)
      • Select Network Setup section and set IP
      • Activate Network Access
    • MEBx Exit
    • Restart and enable PXE boot in bios
  • Install openwsman on servers where ironic-conductor is running:

  • Enable the staging-amt hardware type, power, deploy and management interfaces, for example:

    [DEFAULT]
    enabled_hardware_types = staging-amt,ipmi
    enabled_deploy_interfaces = direct
    enabled_management_interfaces = staging-amt,ipmitool
    enabled_power_interfaces = staging-amt,ipmitool
    

    and restart the ironic-conductor process:

    service ironic-conductor restart
    
  • Enroll an AMT node

  • Specify these driver_info properties for the node: amt_password,

    amt_address, and amt_username

  • Boot an instance

Note

It is recommended that nodes using the pxe_amt* driver be deployed with the local boot option. This is because the AMT firmware currently has no support for setting a persistent boot device. Nodes deployed without the local boot option could fail to boot if they are restarted outside of Ironic’s control (I.E. rebooted by a local user) because the node will not attempt to PXE / network boot the kernel, using local boot solves this known issue.

iBoot driver

Overview

The iBoot power driver enables you to take advantage of power cycle management of nodes using Dataprobe iBoot devices over the DxP protocol.

The staging-iboot hardware type uses iBoot to manage power of the nodes.

Requirements
Tested platforms
Configuring and enabling
  1. Add staging-iboot to enabled_hardware_types and enabled_power_interfaces in /etc/ironic/ironic.conf. Also enable the fake management interface. For example:

    [DEFAULT]
    enabled_hardware_types = staging-iboot,ipmi
    enabled_management_interfaces = fake,ipmitool
    enabled_power_interfaces = staging-iboot,ipmitool
    
  2. Restart the Ironic conductor service:

    service ironic-conductor restart
    
Registering a node

Nodes configured for the iBoot driver should have the driver property set to staging-iboot.

The following configuration values are also required in driver_info:

  • iboot_address: The IP address of the iBoot PDU.
  • iboot_username: User name used for authentication.
  • iboot_password: Password used for authentication.

In addition, there are optional properties in driver_info:

  • iboot_port: iBoot PDU port. Defaults to 9100.
  • iboot_relay_id: iBoot PDU relay ID. This option is useful in order to support multiple nodes attached to a single PDU. Defaults to 1.

The following sequence of commands can be used to enroll a node with the iBoot driver.

  1. Create node:

    openstack baremetal node create --driver staging-iboot \
        --driver-info iboot_username=<username> \
        --driver-info iboot_password=<password> \
        --driver-info iboot_address=<address>
    

References

[1]iBoot-G2 official documentation - http://dataprobe.com/support_iboot-g2.html

Libvirt drivers

Overview

This driver implements Power/Management interfaces for virtual baremetal hardware and is based on Libvirt [1] library and its Python interface. Thus it is suited for testing environments only.

It performs considerably better that Ironic’s SSH driver, especially when there are many virtual baremetal nodes placed on hypervizor [2]. It also supports additional connection transports, including TCP with SASL authentication that can be considered as secure alternative to SSH.

Known drawbacks in comparison to Ironic’s SSH driver are:

  • no support for user+password SSH authentication
  • some use cases possible with SSH driver are not supported
    • e.g. managing VirtualBox VMs on a Windows host from Linux guest

Setting up the environment

  1. Install Ironic

  2. Install ironic-staging-drivers

  3. Install libvirt-python

    • When installing from PyPI, you’d need development version of libvirt package from your distribution (e.g. libvirt-dev in Ubuntu, libvirt-devel in Fedora) and all the usual Python packages required to compile C-extensions in your system (on DevStack, those are already installed when nova-compute is enabled).
  4. Add staging-libvirt to the list of enabled_hardware_types in ironic.conf, configure the power and management interfaces, for example:

    [DEFAULT]
    enabled_hardware_types = staging-libvirt
    enabled_management_interfaces = staging-libvirt
    enabled_power_interfaces = staging-libvirt
    

    Then restart the ironic-conductor service.

  5. Create or update existing virtual baremetal nodes to use one of libvirt-based drivers enabled in the previous step.

  6. Update node properties with driver-specific fields if needed. (see Node driver_info). Default values are suitable for single-node DevStack.

  7. Deploy the node.

Node driver_info
libvirt_uri
(optional) Libvirt URI to connect to. Default is qemu+unix:///system.
ssh_key_filename
(optional) File name of private SSH key when using qemu+ssh:// transport. The file must have appropriate permissions for the user running ironic-conductor service. Default is to use default SSH keys for that user. Note that for private keys with password those must be pre-loaded into ssh-agent.
sasl_username
username to authenticate as. Required when using TCP transport with SASL authentication.
sasl_password
password to use for SASL authentication. Required when using TCP transport with SASL authentication.

Intel NodeManager drivers

Overview

This driver implements support of Intel NodeManager platform via ironic vendor interface methods. Those methods are implemented as sending raw bytes over IPMI. Hardware with Intel NodeManager 1.5 or above is required, feature must be enabled via Flash Image Tool. The driver detects internal addresses of NodeManager device automatically. The main term for NodeManager is policy, which can be power, thermal or boot time. Each policy identified by policy_id (integer number from 0 to 255). Maximum numbers of policies which can be set at the same time limited by platform. For more detailed information see full specification [1].

The staging-nm hardware types extends the ipmi hardware type with support for the staging-nm vendor interface.

Supported vendor passthru methods

In all examples below request/response are JSON bodies in the HTTP request or response.

get_nm_version
HTTP method
GET
Description
Get Intel Node Manager version.

Example of response:

{"firmware": "1.2", "ipmi": "3.0", "nm": "3.0", "patch": "7"}
get_nm_capabilities
HTTP method
GET
Description
Get Intel Node Manager capabilities.

Example of request:

{"domain_id": "platform", "policy_trigger": "none",
 "power_domain": "primary"}

Example of response:

{"domain_id": "platform", "max_correction_time": 100000,
 "max_limit_value": 4096, "max_policies": 16,
 "max_reporting_period": 32768, "min_correction_time": 10,
 "min_limit_value": 100, "min_reporting_period": 100,
 "power_domain": "primary"}
control_nm_policy
HTTP method
PUT
Description
Enable or disable Intel Node Manager policy control.

Example of request:

{"scope": "policy", "enable": false, "policy_id": 10}
set_nm_policy
HTTP method
PUT
Description
Set Intel Node Manager policy. This method creates new policy if provided policy_id is not present or changes current policy.

Example of request:

{"domain_id": "platform", "enable": true, "policy_id": 10,
 "policy_trigger": "none", "action": "alert", "power_domain": "primary",
 "target_limit": 200, "reporting_period": 20000}
get_nm_policy
HTTP method
GET
Description
Get Intel Node Manager policy.

Example of request:

{"domain_id": "platform", "policy_id": 11}

Example of response:

{"action": "alert", "correction_time": 10000, "cpu_power_correction": "auto",
 "created_by_nm": true, "domain_id": "platform", "enabled": true,
 "global_enabled": true, "per_domain_enabled": true,
 "policy_trigger": "none", "power_domain": "primary", "power_policy": false,
 "reporting_period": 20000, "storage": "persistent", "target_limit": 250,
 "trigger_limit": 300}
remove_nm_policy
HTTP method
DELETE
Description
Remove Intel Node Manager policy.

Example of request:

{"domain_id": "platform", "policy_id": 11}
set_nm_policy_suspend
HTTP method
PUT
Description
Set Intel Node Manager policy suspend periods.

Example of request:

{"domain_id": "platform", "policy_id": 10,
 "periods": [{"start": 10, "stop": 60, "days": ["monday", "tuesday"]}]}

For information about time periods calculation please read NodeManager specification.

get_nm_policy_suspend
HTTP method
GET
Description
Get Intel Node Manager policy suspend periods.

Example of request:

{"domain_id": "platform", "policy_id": 13}

Example of response:

{"domain_id": "platform", "policy_id": 13,
 "periods": [{"start": 20, "stop": 100, "days": ["monday", "tuesday"]},
             {"start": 30, "stop": 150, "days": ["friday", "sunday"]}]}
remove_nm_policy_suspend
HTTP method
DELETE
Description
Remove Intel Node Manager policy suspend periods.

Example of request:

{"domain_id": "platform", "policy_id": 13}
get_nm_statistics
HTTP method
GET
Description
Get Intel Node Manager statistics.

Example of request:

{"scope": "global", "domain_id": "platform", "parameter_name": "power"}

Example of response:

{"activation_state": true, "administrative_enabled": true,
 "average_value": 200, "current_value": 202, "domain_id": "platform",
 "maximum_value": 240, "measurement_state": true, "minimum_value": 150,
 "operational_state": true, "reporting_period": 2125,
 "timestamp": "2016-02-03T20:13:52"}
reset_nm_statistics
HTTP method
DELETE
Description
Reset Intel Node Manager statistics.

Example of request:

{"scope": "global", "domain_id": "platform"}

Releasing ironic-staging-drivers

This section is relevant to the maintainers of ironic-staging-drivers. You have to be a member of the ironic-staging-drivers-release group to do releases.

  1. Verify that the CI works via a dummy patch.

  2. Create a signed tag locally:

    git tag -s -m "Release <version>" <version>
    
  3. Push the new tag to gerrit:

    git push gerrit <version>
    
  4. Wait for the new release to appear on PyPI, contact the infra team in case of any issues.

  5. If a stable branch is needed, go to the branches section of the ironic-staging-drivers settings in gerrit and add a new branch from the newly created tag.

  6. If a stable branch has been created, submit a change for it that:

    1. updates .gitreview with a new defaultbranch,
    2. updates extra-requirements.txt with a link to ironic stable,
    3. updates tox.ini to use upper constraints from the corresponding release.

    See the stable/xena patch for an example.